EMT vs IMC vs RMC conduit: which one do you need?

A plain-language comparison of the three steel conduit types used on building and industrial projects, from the supplier of UL-listed conduit in Dammam.

The short answer

EMT

Electrical Metallic Tubing

Thin-wall and unthreaded. It is the lightest and easiest to cut and bend, and is joined with compression or set-screw fittings. Commonly used for indoor, dry locations, above ceilings and in exposed interior runs.

IMC

Intermediate Metal Conduit

A thicker wall than EMT and threaded at the ends. Lighter than RMC while still giving substantial mechanical protection. Used where EMT is not robust enough, including many outdoor runs.

RMC

Rigid Metal Conduit

The thickest wall and the most mechanical protection. Threaded and hot-dip galvanised. Used for outdoor, underground and heavy-duty areas and where the specification calls for maximum protection.

Side-by-side comparison

Wall thickness

EMT
Thinnest
IMC
Medium
RMC
Thickest

Weight

EMT
Lightest
IMC
Medium
RMC
Heaviest

Ends

EMT
Unthreaded
IMC
Threaded
RMC
Threaded

Joining

EMT
Compression or set-screw fittings
IMC
Threaded couplings and fittings
RMC
Threaded couplings and fittings

Finish

EMT
Pre-galvanised
IMC
Hot-dip galvanised
RMC
Hot-dip galvanised

Standards

EMT
UL 797 / ANSI C80.3
IMC
UL 1242 / ANSI C80.6
RMC
UL 6 / ANSI C80.1

Mechanical protection

EMT
Basic
IMC
High
RMC
Highest

How to choose

  1. 1Start with the project specification and the consultant's requirements. They decide which type is allowed for each area.
  2. 2Match the conduit to the environment: indoor and dry areas, outdoor and wet areas, underground, or areas exposed to impact.
  3. 3Consider installation: EMT is quickest to cut, bend and install; threaded IMC and RMC take more labour but give more protection.
  4. 4Use fittings that match the conduit type, and keep to one system and one supplier where possible so parts are compatible.

This guide is general information. Always confirm the conduit type with your project specification, consultant and the applicable Saudi and client standards.

See our full conduit range

Frequently asked questions

What is the difference between EMT, IMC and RMC conduit?

They are three grades of steel conduit. EMT is thin-wall and unthreaded, IMC has a thicker threaded wall, and RMC has the thickest threaded wall and gives the most mechanical protection. Wall thickness, weight and the way they are joined all differ.

Which conduit is easiest to install?

EMT. It is lighter, can be bent with a standard hand bender, and does not need threading because it uses compression or set-screw fittings.

Can EMT be used outdoors?

EMT is mainly used indoors and in dry locations. For outdoor, underground or heavy-duty areas, specifications commonly call for IMC or RMC. Always follow the project specification.

Is the conduit you supply UL-listed?

Yes. The steel conduit systems, fittings and electrical boxes we supply are UL-listed and made in Saudi Arabia, in sizes from ½ inch to 2 inch.

How do I get a quotation?

Send us your bill of quantities or project specification through the contact page or on WhatsApp, and we will reply with availability, pricing and delivery.

Need a conduit systems quotation?

Send us your BOQ or project specification and we'll come back with availability, pricing and delivery.

Request a Quote